Connect Summit to Open Integration Engine so patients reach EPD at check-in and the full packet updates the same EPD record.

Configure EPD Integration when your practice needs patients to flow from Summit into Open Integration Engine for HL7 ADT processing: registered in EPD as soon as they check in, then updated when they finish the intake packet.

Who does this: Clinic administrators configure Summit. Integration administrators configure Open Integration Engine on the clinic network.

How It Works

Summit does not send directly to EPD. Summit creates an outbound EPD job, and Open Integration Engine polls Summit over HTTPS, claims the job, fetches the canonical patient payload, transforms it into HL7 ADT, and posts the ACK/status back to Summit.

When EPD sync is enabled, matching intakes automatically queue registration on entry, before the full packet:

WhenWhat Summit sendsResult in EPD
A patient starts a matching QR/kiosk intake and no patient/facility registration already existsADT A04 — registerQueued for the bridge; confirm patient and visit creation in EPD.
The patient submits the full packet and an A04 exists for that same intake sessionADT A08 — updateWaits for the same-intake registration's accepted ACK before sending packet data.
A completed intake has no same-intake A04, including when only historical patient registrations existADT A04 — registerUses the completed-intake registration workflow. Repeated completion does not create another job.
Staff add a patient by hand, Sync patients created by staff is on, and no registration already existsADT A04 — registerQueued for the bridge; confirm the intended patient/visit workflow.

Early-entry and staff-created registration deduplicate by patient/facility. Completed-intake registration is scoped to the intake. A historical or staff-created A04 does not turn a different intake into A08 or unlock its update. Existing uncertain same-intake registrations are not replaced automatically. Actual EPD patient/visit behavior and delivery timing require clinic acceptance.

Summit always looks for the same person already in Summit (name, date of birth, phone, and email). A possible match or incomplete duplicate search holds the registration for the front desk. Missing required demographics, or a date of birth that is not a real date, also cause review. These safeguards cannot be disabled. See Review held registrations.

Before You Start

  • Confirm you can access Settings in Summit.
  • Confirm the intake packet or form that should trigger EPD sync already exists.
  • Install Open Integration Engine on the workstation or server that will act as the local bridge.
  • For Windows, use the Open Integration Engine release approved by your implementation lead. If Java is not already managed on the machine, choose the Windows x64 installer that includes a JRE.
  • Confirm the Open Integration Engine backend is running. A healthy local install usually shows Service Available at https://localhost:8443 or https://127.0.0.1:8443.

EPD production sending: Do not point this channel at production EPD until the EPD listener host and port are confirmed by the vendor.

Configure Summit

Open Settings.

Open Clinical Workflow.

Open EPD Integration.

Turn Enable EPD sync on when the clinic is ready for matching intakes to register patients on entry and synchronize on completion.

Review the facility and HL7 fields.

Use the facility code assigned for the clinic or pilot site. For local Frisco pilot testing, keep the configured Frisco facility value unless your implementation lead gives you a different code.

Select the Trigger intake packets dropdown and choose the intake packet or packets that should create EPD jobs.

Select the Trigger forms dropdown if individual forms should also trigger EPD jobs.

Turn Sync patients created by staff on if a patient that staff add by hand in Summit should be registered in EPD right away.

Leave it off if staff also add patients who are not visiting today, such as for a future appointment, because each registration creates a visit in EPD. Accepting a referral also counts as staff adding a patient.

Choose the send mode.

Use automatic sending only when the bridge should be allowed to poll eligible jobs immediately. Use review mode when staff should inspect jobs before they are released to the bridge.

Registration on intake entry and possible-duplicate review are required whenever EPD sync is enabled; there are no separate switches for them. A completed intake uses A08 when an A04 already exists for that same intake. The update waits for accepted registration evidence.

Select Save changes.

Monitor heartbeats and pending work

After saving the integration, use the separate EPD monitoring card. Monitoring is off until you enable and save it; the timeout fields appear once the switch is on. The integration must be enabled and an administrator must configure the developer email destination before monitoring can be turned on. The Encounters feature is not required.

  • Heartbeat timeout: default 5 minutes; allowed range 2–60 whole minutes. Missing heartbeats raise an alert even when polling continues. This reports a heartbeat fault, not proof that EPD is offline.
  • Pending delivery timeout: default 10 minutes; allowed range 2–1440 whole minutes. This monitors jobs waiting in pending or retrying. Claimed jobs, manual holds and uncertain deliveries still require ledger review.
  • Checks run every minute. Each incident produces an opening event and a recovery event; repeated checks do not create repeated opening events. Email retries can still duplicate a message after an uncertain provider result.
  • The card shows the last check, active conditions and alert delivery failures. An email service accepting a message does not prove it reached the developer mailbox. Older failures remain visible under the current monitoring configuration even when a later alert succeeds.
  • Disabling EPD sync pauses monitoring. Disabling monitoring leaves patient synchronization unchanged. Monitoring never resends jobs, marks them accepted or changes EPD patient records.

If the card says the alert destination is not configured, contact your integration administrator. Heartbeat and queue monitoring do not prove every patient reached EPD; review unresolved records in the Sync Ledger.

Generate Bridge Credentials

In Bridge credentials, enter the OIE channel name.

Use a clear name such as Summit EPD ADT.

Enter the OIE host name and version if you want them visible in bridge status.

These fields help staff recognize which OIE machine is polling Summit. They do not replace the authentication credentials.

Select Generate credentials.

Copy or download the generated credentials immediately.

The bridge secret is shown only once. If it is lost, generate a new credential set and update OIE.

Keep credentials private: The generated bridge secret allows OIE to poll Summit. Do not paste it into tickets, chat logs, screenshots, or shared documents.

Configure Open Integration Engine

Start by loading the Summit bridge values into the Open Integration Engine Configuration Map.

In Summit, select Download map file from the generated credentials panel.

The downloaded file contains only Configuration Map key/value rows.

Open the Open Integration Engine Administrator or client.

If the browser service page is open, use the webstart.jnlp launcher to open the Administrator. Sign in with the OIE administrator credentials configured for the local installation.

Open Settings.

Open Configuration Map.

Choose Import Map.

Select the downloaded summit-epd-oie-config-map.properties file.

Confirm these keys appear in the Configuration Map:

  • zscribeBaseUrl
  • zscribeBridgeId
  • zscribeBridgeSecret
  • summitHl7OutDir

Select Save.

The map file stores the connection values only. It does not create an OIE channel by itself.

Downloaded map file contains credentials: Treat the downloaded file like a secret because it includes the bridge credential.

Manual Copy Option

Use this path if you do not want to import a file.

In Summit, copy the Credentials for OIE Configuration Map block.

In Open Integration Engine, open Settings -> Configuration Map.

Add these keys manually:

  • zscribeBaseUrl
  • zscribeBridgeId
  • zscribeBridgeSecret
  • summitHl7OutDir, if local file output is used

Select Save.

Channel Setup and Testing

Use the existing demographics form and its packet; a separate quick-check-in form is not required.

The settings page provides Copy source script and Copy ACK script. These scripts prepare HL7 for an OIE transport destination and report the destination's real acknowledgment. They are not a local file-writing channel and must not be configured with a no-op destination when testing delivery.

For OIE testing:

  1. Use an isolated test channel, development bridge credentials, and an approved test receiver or test EPD.
  2. Configure the source as a JavaScript Reader using the copied source script. Use a 5–10 second interval and one processing thread for testing.
  3. Configure the approved MLLP/TCP destination and ACK response handling using the copied ACK script. Match zscribeEpdDestinationName to the destination name (default EPD).
  4. Confirm the destination and facility before deploying the test channel. Keep production channels separate.
  5. Submit the existing demographics/registration entry and confirm an A04 job appears before completing the packet.
  6. Complete the same patient's packet. The A08 must wait until the A04 has an accepted ACK. Confirm both the patient and visit in test EPD when that system is available.

For file-only simulation, run bun run epd:mock-bridge with development bridge environment variables. It writes an HL7 file and reports local_simulation_written; it never reports EPD acceptance. Therefore a simulated A04 does not release its dependent A08. Do not manufacture an ACK to make the queue advance.

The repository's docs/technical/clinical-workflows/epd-registration-testing.md contains the full local, test-receiver, and supervised production checklist, including commands, failure cases, and evidence requirements.

What Staff See

The ledger shows the current sync state for outbound EPD jobs. Staff can use it to confirm whether a registration or update is pending, claimed by the bridge, accepted by ACK, failed, or waiting for review.

Review Held Registrations

Summit holds a registration instead of sending it when the patient may already exist in Summit:

  • Exact match: same name, date of birth, and phone or email.
  • Near match: two of the three — for example a new phone number, a typo in the name, or twins on a shared family phone.

A parent's phone reused for a child is not a match on its own. Summit never merges records or picks one for you.

When a registration is held:

The front desk gets a Possible Duplicate Patient item in the inbox.

Select Review EPD Hold. It opens the intake, or the patient's chart when staff created the patient by hand.

Compare the patient with the Possible matches in Summit list. Each match shows the name, date of birth, MRN, and which details are the same. Search EPD for the patient as well.

Choose one:

  • Send to EPD when this is a different person. The registration goes to EPD, followed by any packet update that was waiting on it.
  • Don't send when the patient already exists in EPD. Summit closes the registration and its packet update. Update the existing EPD record by hand.

Packet updates wait for registration: an A08 cannot be polled, claimed or manually released until an A04 for the same intake has an accepted ACK or an authorized staff confirmation of the existing EPD patient and visit. Another intake's registration does not qualify. Pending dependencies wait up to 30 minutes before staff review; releasing an A04 review hold starts a fresh wait for its dependent updates. A matching accepted ACK or staff confirmation releases registration-only holds. Independent manual holds still need a staff decision. Don't send does not verify registration or merge records.

Confirm a registration already present in EPD

An A04 with uncertain delivery, rejection or exhausted delivery attempts may still need reconciliation. Open its intake or patient chart and find the EPD review card. Before confirming, search the receiving EPD and verify the correct patient, facility and intended visit for this registration.

If both records exist, choose Confirm registration in EPD, enter the EPD patient reference, visit reference and a review note, then confirm. This requires permission to manage intakes. Summit records who confirmed it and when, and releases updates held only for that registration. It does not resend the A04, invent an ACK or replace the original transport status and attempts. The ledger may therefore still show the original delivery failure after staff confirmation.

If the patient or intended visit is absent, do not confirm. Ask the integration owner to investigate the failed registration and arrange the correct registration workflow. This confirmation action cannot create a missing EPD record or safely retry an uncertain delivery. Do not use it for file-only simulations.

Review and export sync history

Open Sync Ledger to review registration and packet-update jobs, including registrations created by staff. Use Load more to read older pages. Jobs appear even when they have no lifecycle event.

To narrow the history, enter creation dates, then select Apply / refresh. Both dates use UTC; the Through date includes the whole day. Leave the fields empty for all available history.

Select Export CSV to download all matching jobs, including pages you have not opened. It includes message-control IDs, ACK details, attempts and safe errors. A cancelled or failed export does not download a partial file. The file contains patient identifiers; keep it in the clinic-approved location.

The ledger includes jobs created through the last refresh. Delivery statuses can change while pages load or export. Refresh to include newer jobs. An accepted ACK confirms the receiver's response; staff must still verify the intended patient and visit in EPD. The ledger does not identify patients for whom no sync job was ever created, and exporting does not resend or change jobs.

Troubleshooting

No EPD job appears after a patient checks in or completes an intake. Confirm EPD sync is enabled, the intake uses a configured trigger packet or form, and the patient checked in after the settings were saved.

Staff added a patient but no EPD job appears. Turn on Sync patients created by staff. Patients added before the setting was turned on are not sent.

A job shows Needs review. The registration is held, usually for a possible duplicate. Open the item from the inbox and choose Send to EPD or Don't send. A job held because the patient record is incomplete, or its date of birth cannot be read, can be sent only after the patient record is corrected.

Only an update (A08) is waiting. Check the registration for that same intake first. Send remains disabled while the prerequisite lacks accepted registration evidence or required demographics are missing. Investigate rejection/uncertain delivery without blindly resending. If the correct EPD patient and visit already exist, use the audited confirmation workflow above. Existing queued A08 jobs are not automatically converted to A04. After a matching accepted ACK or staff confirmation, allow the next due poll or resolve any independent manual hold.

OIE cannot poll Summit. Check the zscribeBaseUrl, bridge ID, and bridge secret. The base URL should be the Convex HTTP site URL shown by Summit, not the staff dashboard URL.

The OIE Administrator does not open. Confirm the OIE backend service is running at https://localhost:8443. If the Java launcher fails, install or repair OpenWebStart and download a fresh webstart.jnlp from the OIE service page.

No HL7 file is written locally. Confirm the OIE channel is deployed and started, then check the output folder path and Windows permissions.

The channel runs but no messages appear. Confirm a patient has checked in or completed a trigger packet after EPD sync was enabled, and that the job is not waiting for review. OIE only receives jobs that are pending or retrying.

The channel logs missing Configuration Map values. Open Settings -> Configuration Map and confirm zscribeBaseUrl, zscribeBridgeId, and zscribeBridgeSecret are present and saved.

The job does not show an ACK in Summit. Confirm the OIE channel can post back to the ACK endpoint using the same bridge credentials.

Production EPD sending is not working. Do not troubleshoot production MLLP/TCP until the EPD listener host and port are confirmed by the vendor.


Need help? Contact your administrator or reach out to support.